-40%

Outback Power FM80 FlexMax 80 MPPT 80 Amp Solar Charge Controller

$ 237.07

Availability: 100 in stock
  • Model: FM80
  • Refund will be given as: Money Back
  • MPN: FM80
  • Non-Domestic Product: No
  • Power Source: Solar
  • Type: Charger/Inverter
  • All returns accepted: Returns Accepted
  • System Configuration: Off-Grid
  • Item must be returned within: 30 Days
  • Color: Black
  • Modified Item: No
  • Condition: New
  • Return shipping will be paid by: Seller
  • Custom Bundle: No
  • Features: LCD Display
  • Connector Configuration: FM
  • Brand: OutBack Power
  • Application: Home/Garden
  • Product Line: OutBack Flexmax

    Description

    Outback Power Systems
    FLEXmax 80
    MPPT Charge Controller
    The
    FLEXmax 80
    is the latest innovation in Maximum Power Point Tracking (MPPT)
    charge controllers
    from OutBack Power Systems. The FLEXmax 80’s innovative MPPT algorithm is both continuous and active, increasing your renewable energy yield up to 30%. Thanks to enhanced cooling, the
    FLEXmax 80
    can operate at its full 80 amp maximum current rating in ambient temperatures as high as 104°F (40°C).
    Included in the FLEXmax 80 are all of the features first developed by OutBack Power in the revolutionary MX60, such as support for a wide range of nominal battery voltages and the ability to step-down a high voltage solar array to recharge a low voltage battery. A built-in backlit display shows status information at the touch of a button. Enhanced network communications allow the FLEXmax 80 to be remotely programmed via the optional MATE system display and controller.
    The new FLEXmax 80 is the only choice when you demand a high performance, efficient and customizable charge controller for your advanced power system.
    Features:
    Increases PV Array Output by up to 30%
    Advanced Continuous Maximum Power Point Tracking Algorithm
    Full Output Capacity in Ambient Temperatures up to 104°F (40°C)
    Battery Voltages from 12 VDC to 60 VDC
    Automatic Battery Voltage Detection at Start Up
    Fully OutBack Network Integrated and Programmable
    Programmable Auxiliary Control Output
    Negative or Positive Ground System Capable
    Built-in 128 days of Data Logging
    FLEXmax™ 80 Specifications*
    Nominal Battery Voltages
    12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up)
    Maximum Output Current
    80 amps @ 104° F (40°C) with adjustable current limit
    Maximum Solar Array STC Nameplate
    12 VDC systems 1250 Watts / 24 VDC systems 2500 Watts / 48 VDC systems 5000 Watts / 60 VDC Systems 7500 Watts
    NEC Recommended Solar Array STC Nameplate
    12 VDC systems 1000 Watts / 24 VDC systems 2000 Watts / 48 VDC systems 4000 Watts / 60 VDC Systems 5000 Watts
    PV Open Circuit Voltage (VOC)
    150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum
    Standby Power Consumption
    Less than 1 Watt typical
    Power Conversion Efficiency
    97.5% @ 80 Amps in a 48 VDC System - Typical
    Charging Regulation
    Five Stages: Bulk, Absorption, Float, Silent and Equalization
    Voltage Regulation Set points
    10 to 80 VDC user adjustable with password protection
    Equalization Charging
    Programmable Voltage Setpoint and Duration - Automatic Termination when completed
    Battery Temperature Compensation
    Automatic with optional RTS installed / 5.0 mV per °C per 2V battery cell
    Voltage Step-Down Capability
    Can charge a lower voltage battery from a higher voltage PV array - Max 150 VDC input
    Programmable Auxilary Control Output
    12 VDC output signal which can be programmed for different control applications (Maximum of 0.2 amps DC)
    Status Display
    3.1" (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total
    Remote Display and Controller
    Optional Mate or Mate2 with RS232 Serial Communications Port
    Network Cabeling
    Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires)
    Data Logging
    Last 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of production
    Hydro Turbine Applications
    Consult factory for approved Turbines
    Positive Ground Applications
    Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications)
    Operating Temperature Range
    Minimum -40° to maximum 60° C (Power capacity of the controller is automatically derated when operated above 40° C)
    Environmental Rating
    Indoor Type 1
    Physical Specifications
    Conduit Knockouts
    One 1" (35mm)on the back; One1" (35mm) on the left side; Two 1" (35mm) on the bottom
    Warranty
    Standard 5 year
    Weight
    - Unit, 12.20 lbs (5.56 kg)
    - Shipping, 15.75 lbs (7.10 kg)
    Dimensions
    - Unit 16.25" x 5.75" x 4" (41.3 x 14 x 10 cm) - (H x W x D)
    - Shipping 21" x 10.5" x 9.75" (53 x 27 x 25 cm)
    Options
    Remote Temperature Sensor (RTS), HUB 4, HUB 10, MATE, MATE 2
    Menu Languages
    English & Spanish
    OutBack Power provides a five (5) year limited warranty against defects in materials and workmanship, and a two (2) year limited warranty against fan failure