-40%

60A 100A MPPT Solar Charge Controller Battery Regulator Charger 12V/24V PV 100V

$ 42.23

Availability: 61 in stock
  • select: MPPT-40A
  • Wattage: 400W-1600W
  • Voltage Input: 12V/24V
  • Load output: 5A
  • Colour: White
  • Condition: New
  • Brand: OOYCYOO
  • Battery type: Acid battery/lithium battery
  • Charging: 3-stage:constant current(MPPT), constant voltage
  • Product Type: Solar charger

    Description

    20A 30A 40A 60A 100A MPPT So
    lar Charge Controller Battery Regulator Charger 12/24V PV 100V
    MPPT 20A
    12V system : Open circuit voltage≤48V(Voc)   Max .PV input Power:300W
    24V system: Open circuit voltage≤96V(Voc)    Max .PV input Power:600W
    MPPT 30A
    12V system : Open circuit voltage≤48V(Voc)   Max .PV input Power:400W
    24V system: Open circuit voltage≤96V(Voc)    Max .PV input Power:800W
    MPPT 40A
    12V system : Open circuit voltage≤48V(Voc)   Max .PV input Power:500W
    24V system: Open circuit voltage≤96V(Voc)    Max .PV input Power:1000W
    MPPT P60A
    12V system : Open circuit voltage≤48V(Voc)   Max .PV input Power:750W
    24V system: Open circuit voltage≤96V(Voc)    Max .PV input Power:1500W
    MPPT K100A
    12V system : Open circuit voltage≤48V(Voc)   Max .PV input Power:1300W
    24V system: Open circuit voltage≤96V(Voc)    Max .PV input Power:2600W
    Overview:
    MPPT series solar charge controller is based on an advanced maximum power point tracking (MPPT) technology developed, dedicated to the solar system, the charge controller conversion efficiency up to 98%.
    This series MPPT have such advantages:
    All the Various Real-time data show on one display ,Convenient user to check
    The Solar Panel input voltage up to 100V, suitable for various specifications of solar panel
    The power supply uses ultra low power chip ,reducing static standby power consumption ,reduce energy loss
    Dual USB 5V Output for phone charging
    Support Remote Display
    Feature:
    Advanced Maximum Power Point Tracking (MPPT) technology, with efficiency no less than 99.5%.
    High quality components, perfecting system performance, with maximum conversion efficiency of 98%.
    Ultra-fast tracking speed and guaranteed tracking efficiency.
    Wide MPP operating voltage range.
    12/24VDC automatically identifying system voltage.
    LCD panel display design, dynamically displaying tool‟s operating data and working condition.
    Support 3 charging lead-acid battery options: Sealed, Gel, Flooded.
    Charge mode: three stages (constant current, constant voltage, floating charge), it prolongs service life of the batteries.
    Battery temperature compensation function.
    Multiple load work modes
    This solar charge controller with three time function.
    A: time (night working) B: period (pause) C: time slot (dawn working)
    Package Including:
    1PCS MPPT Solar Controllers
    1PCS User Manual (English)
    1PCS Temperature Sensor
    Function:
    "P" series of an intelligent, multi-purpose solar charge controller
    LCD screen display
    Battery reverse discharge protection
    Simple (and more time control) operation
    Battery reverse polarity protection
    MPPT charging mode
    Battery under voltage protection
    Parameter user can reset
    Overload, short-circuit protection
    A key to open and close the load
    Automatic temperature compensation function
    A key to restore the factory settings
    USB5V charge 2.4A
    LCD Operating interface description :
    Network Line Interface (RS485) Indicator: Green light represents the battery, green light flashes, indicating that the load is working properly; yellow light indicates solar energy; yellow light flashes, indicating solar energy charging;
    Parameter Table:
    Model
    MPPT P40
    MPPT P60
    Maximum power current
    40A
    60A
    Battery Votlage
    12V 24V Auto
    Battery float voltage
    13.8V(12V system)/27.6V(24V system)
    Battery (under voltage) protection
    10.6V(12V system)/21.2V(24V system)
    Battery (under voltage) recovery voltage
    12.6V(12V system)/25.2V(24V system)
    Solar Panel Maximum open circuit voltage(Voc)
    ≤48V(Voc)12V system ;  ≤96V(Voc)24V system
    Maximum open circuit voltage of the solar panel (Voc)
    18V-48V(12V system) / 36V-96V(24V system)
    Maximum PV input power
    520W(12V system)
    1040W(24V system)
    750W(12V system)
    1500W(24V system)
    System load loss
    ≤13mA
    Loop Buck
    ≤100mV
    Operating Temperature
    -10°C~60°C
    Storeage Temperature
    -30°C~70°C
    Humidity requirements
    ≤90%, No condensation
    Temperature compensation
    -4mV/Cell/°C
    Installaton Lin(mm2)
    8mm2
    10mm2
    Installaton Line(AWG)
    10(AWG)
    10(AWG)
    Batery capacity configuration
    ≥300AH
    ≥400AH
    Photo:
    Product Description
    40A  60A MPPT Solar Charger Controller for 12V/24V/36V/48VDC Batteries
    100% MPPT controller
    Intelligent Maximum Power Point Tracking technology
    Built-in DSP controller with high performance
    Automatic battery voltage detection 12V/24V/36V/48V
    Three-stage charging optimises battery performance
    Multi-function LCD displays
    Reverse polarity protection of solar panel
    Overcharge protection
    Can be mounted easily
    Suitable for battery types of sealed lead acid, vented Gel, and Lithium battery
    Notes: The output terminal is for lamp only
    ( 12V system less 60W, 24V/36V/48V system less 100W ),
    and it will be burnt if connecting to other loads.
    The output for the battery is no polarity reverse protection.
    Datasheet:
    Model No
    MPPT-30A
    MPPT-40A
    MPPT-50A
    MPPT-60A
    Charging mode
    MPPT Maximum power point tracking automatically
    Charging
    3-stage

    constant current(MPPT), constant voltage(Absorption Voltage), floating charge
    System type
    DC12V/24V/36V/48V Recognition automatically
    System voltage automatic recognition
    12V system (DC9V-DC15V)
    24V system (DC18V-DC29V)
    36V system (DC30V-DC39V)
    48V system (DC40V~DC60V)
    Soft start time
    ≤1S
    ≤1S
    ≤1S
    ≤1S
    Dynamic response and recovery time
    100us
    100us
    100us
    100us
    Max efficiency
    ≥98.1%
    (Voc is 1.5 or 2 times than battery, then it’s best efficiency)
    PV utilization
    ≥99%
    ≥99%
    ≥99%
    ≥99%
    Input specification
    Voc from PV
    ( Make sure the Voc of PV meeting the requirement as right. Voc is 1.5 or 2 times than battery, then it’s best efficiency. )
    12V system (DC20V~DC80V)
    24V system (DC37V~DC105V)
    36V system (DC50V~DC160V)
    48V system (DC72V~DC160V)
    The maximum PV input voltage (Voc)
    DC190V
    (The controller can’t work at this voltage of long duration that will break controller. Please refer to Input voltage from PV.)
    The maximum PV input power
    (The total power rated of PV can’t be over this watt that will break the controller.)
    12V system (400W)
    24V system (720W)
    12V system (480W)
    24V system (960W)
    12V system (600W)
    24V system (1200W)
    12V system (720W)
    24V system (1440W)
    36V system (2100W)
    48V system (2800W)
    Output specification
    Selectable battery type(default is Sealed)
    Vented/ Sealed / Gel / NiCd / Lithium battery
    (defined voltage for other battery by user)
    Absorption Charging Voltage
    Refer to Batteries charging reference
    Floating Charging Voltage
    Refer to Batteries charging reference
    Overcharging protection voltage
    12V system (15V)
    24V system (30V)
    36V system (45V)
    48V system (60V)
    Rated output current
    30A
    40A
    50A
    60A
    Temperature Coefficient
    ±0.02%/ centi-degree
    Automatic temperature compensation
    14.2V-

    Max temperature-25 centi-degree

    *0.3
    Output voltage ripple-peak
    100mV
    100mV
    100mV
    100mV
    Output voltage accuracy
    ≤±1%
    ≤±1%
    ≤±1%
    ≤±1%
    Indicating
    LCD display
    See LCD display instruction
    See LCD display instruction
    See LCD display instruction
    See LCD display instruction
    LED display
    CPU working indicator
    CPU working indicator
    CPU working indicator
    CPU working indicator
    Protection function
    Output over-voltage protection
    See output specification
    See output specification
    See output specification
    See output specification
    Input Anti-intrusion protection
    yes
    yes
    yes
    yes
    Temperature Protection
    75 centi-degree
    75 centi-degree
    75 centi-degree
    75 centi-degree
    Temperature increased protection
    Output power will reduce when it’s more 70 centi-degree.
    Output power will be normal when it’s less 55 centi-degree.
    Fan-on temperature
    >40 centi-degree
    >40 centi-degree
    >40 centi-degree
    >40 centi-degree
    Fan-off temperature
    <35 centi-degree
    <35 centi-degree
    <35 centi-degree
    <35 centi-degree
    Other parameters
    Acoustic noise
    ≤40dB
    ≤40dB
    ≤40dB
    ≤40dB
    Cooling way
    Forced air cooling.
    Components
    Imported materials

    Accord  to EU standards, Industrial grade range.
    Environmental requirements
    Meet 2002/95/EC; No cadmium, hydrides and fluorides
    Properties
    Size (mm)
    210x210x85
    210x210x85
    210x210x85
    210x210x85
    Net weight(Kg)
    1.25
    1.25
    1.35
    1.35
    Gross weight(Kg)
    1.35
    1.35
    1.45
    1.45
    Security Level
    According to CE

    PSE

    FCC

    EMC,EN60950
    Electromagnetic Compatibility
    According to EN61000

    EN55022

    EN55024
    Enclosure
    IP21
    IP21
    IP21
    IP21